Permissible as single fastening. Permissible load in cracked and non-cracked normal concrete of strength ≥ C20/25. Manufacturer’s information has to be observed strictly (ETA-05/0069).

galvanized, according to DIN EN ISO 19598 / DIN EN ISO 2081
LminMinimum drilling depthdiameterdiametert material thicknessPzul permissible tractive forcePzulR30 permissible tensile load under the influence of fire (30min)PzulR90 permissible tensile load under the influence of fire (90min)weight
SDK 10/1055 mm10 mm10 mm0-10 mm4,3 kN1,8 kN1,8 kN5,88 kg/100
SD 8/1055 mm8 mm8 mm0-10 mm3,6 kN1,4 kN0,9 kN3,5 kg/100
SD 8/3055 mm8 mm8 mm0-30 mm3,6 kN1,4 kN0,9 kN4,4 kg/100
SD 10/1075 mm10 mm10 mm0-10 mm5,7 kN2,8 kN1,9 kN6,2 kg/100
SD 10/3075 mm10 mm10 mm0-30 mm5,7 kN2,8 kN1,9 kN7,8 kg/100
SD 12/1090 mm12 mm12 mm0-10 mm9,5 kN5,0 kN3,2 kN11 kg/100
SD 16/25110 mm16 mm16 mm0-25 mm13,4 kN9,4 kN6,0 kN26,3 kg/100
Stainless steel, according to ASTM 31 Ti / AISI 316 L, BS 320S17 / BS 316S11
LminMinimum drilling depthdiameterdiametert material thicknessPzul permissible tractive forcePzulR30 permissible tensile load under the influence of fire (30min)PzulR90 permissible tensile load under the influence of fire (90min)weight
SD 8/10E455 mm8 mm8 mm0-10 mm3,6 kN1,4 kN0,9 kN3,6 kg/100
SD 10/10E475 mm10 mm10 mm0-10 mm5,7 kN2,8 kN1,9 kN6,2 kg/100
SD 10/30E475 mm10 mm10 mm0-30 mm5,7 kN2,8 kN1,9 kN7,1 kg/100
SD 12/10E490 mm12 mm12 mm0-10 mm9,5 kN5,0 kN3,2 kN10,9 kg/100